LPC845-BRK: deploy must always unwedge the shared VCOM (pyocd/SWD flash leaves CDC in Windows error 31) #565
Flashing the LPC845-BRK via pyOCD/SWD wedges the board's shared USB VCOM on Windows: after a flash the CDC serial port goes to Device Manager error 31 ("This device cannot start") and only a physical USB replug brings it back. This breaks any flash-then-monitor flow (e.g. the FastLED AutoResearch RPC harness), which must reopen the serial port immediately after deploy.
Requirement: deploy must always unwedge — after every flash the VCOM must be usable again with no physical intervention.
Why this happens
The LPC845-BRK's on-board debug probe is a USB composite device exposing both a CMSIS-DAP HID interface and a CDC VCOM bridge (wired to P0_24/P0_25, per crates/fbuild-build/src/nxplpc/assets/arduino_stub/HardwareSerial.cpp). pyOCD opens the CMSIS-DAP HID to flash over SWD; its post-flash target reset leaves the composite device's CDC function wedged on Windows (error 31). Observed workaround so far is "don't issue a pyocd reset after flash" + physical replug.
Current state in fbuild
There is no LPC deployer wired yet. The daemon's platform dispatch falls through to:
crates/fbuild-daemon/src/handlers/operations/deploy.rs:707
"deployer for {:?} not yet implemented", // Platform::NxpLpc lands here
So today the board is flashed by pyOCD outside fbuild, with no recovery step — hence the manual replug. This is the deploy gap tracked by #551; this issue adds the "always unwedge" acceptance criterion to it.
Proposed fix
Implement an fbuild-deployDeployer for Platform::NxpLpc that owns the unwedge:
Prefer lpc21isp ISP-over-UART (the README's primary path, upload.protocol in lpc845brk.json). ISP flashing runs over the VCOM serial line itself and never opens the CMSIS-DAP HID, so the composite device cannot wedge. This is the cleanest "always unwedge."
If SWD/pyOCD is used, own a deterministic post-flash recovery instead of leaving it to pyocd's default:
Skip pyocd's post-flash reset (the step correlated with the wedge); rely on the baked-in vector checksum + a clean DAP disconnect to start the image.
If the VCOM is still wedged, force a Windows USB re-enumeration of the composite devnode (restart the device / cycle the port) before returning success — modeled on the existing TeensyDeployer state machine, which already "takes a wedged Windows host and recovers it" (crates/fbuild-deploy/src/teensy/).
Verify on hardware (LPC845-BRK): flash → reopen VCOM → AutoResearch RPC echo succeeds with no replug.
Acceptance
fbuild deploy <lpc845 project> -e lpc845brk flashes and the VCOM is immediately openable afterward, repeatably, with zero physical replugs.
/clud-fix burn-down — skipped (downstream of #551)
Touched as part of the #586 meta sweep. This issue is strictly downstream of #551 (no LPC Deployer exists yet, so there's nothing to attach the VCOM-unwedge logic to). Investigation report on #551 sketches the planned fix shape — including a dedicated vcom_unwedge.rs module specifically for the acceptance criterion this issue tracks. Will re-attempt this one automatically once #551 lands the LPC deployer scaffold.
Filed via Claude Code — /clud-fix skill burn-down pass.
Confirmed wedge on 2026-06-15 with refined repro + likely actual trigger
Reproduced today running bash autoresearch lpc845brk --pin-toggle-rx --upload-port COM10 on Windows 10 against the LPC845-BRK. The wedge is real and consistent. Adding more diagnostic detail because the probable trigger is different from what this issue's original body assumed -- and that changes the fix shape.
What FastLED's autoresearch actually does today
ci/autoresearch/phases.py:1684-1716 invokes two separate pyocd subprocesses back-to-back:
Each subprocess opens and closes the CMSIS-DAP HID interface independently. On the LPC845-BRK that interface is part of a composite USB device that also exposes the application VCOM CDC.
Observation today, after the merged work
I retested with the architected workarounds in place:
pyocd is using --no-reset on the load + reset_type=sw (NVIC SYSRESETREQ) on the separate commander -- not a hardware SRST, so the original "post-flash reset toggles the probe" hypothesis is ruled out for this exact code path.
The CMSIS-DAP probe firmware on the LPC4322 / on-board debugger is not observably reset by reset_type=sw (which is a target-side NVIC write, transparent to the probe).
And yet the CDC VCOM still wedges into Windows error 31 every single time. Reproducibly. The follow-up sequence is:
pyocd commander -O reset_type=sw -c reset -c go -c quit -- opens HID again, sends NVIC reset to the target, closes HID. (Subprocess cdc on boot warning #2 exits.)
Within ~50 ms of step 2, the Windows CDC sibling drops to error 31 and stays there until physical USB replug.
The fact that this still happens with --no-reset + reset_type=sw means the wedge trigger is not the reset itself. It is something about the second HID open-close cycle on a composite device that confuses Windows' CDC driver.
Refined root-cause hypothesis
The Windows usbccgp.sys (USB composite class generic parent driver) treats CMSIS-DAP HID + CDC as two function drivers under one device. When pyocd opens the HID, usbccgp serializes the HID interface. When pyocd closes it and then a different process re-opens it within a short window, usbccgp emits a function-level reset event on the device. That function-level reset doesn't affect the HID side (pyocd just re-handshakes) -- but the CDC sibling sees its endpoint cleared and the higher-level usbser.sys driver doesn't recover, going to error 31.
Two practical implications:
A single pyocd invocation that does load + reset would likely sidestep this. Either pyocd flash --reset (full unified command) or pyocd load -O reset_type=sw firmware.bin (single subprocess, default-on reset) keeps the HID open for the whole sequence.
The --no-reset + separate commander pattern is the active trigger, not the reset semantic. This is why reset_type=sw (which was added specifically for VCOM safety) doesn't save us -- it's not the reset that wedges the CDC, it's the inter-subprocess HID re-open.
Proposed fix for the autoresearch path (one-line in ci/autoresearch/phases.py)
Collapse the two subprocesses into one:
# Single subprocess: load + reset_type=sw all in one HID sessionload_cmd=pyocd_cmd_prefix+ [
"load", "--target", target,
"-O", "reset_type=sw", # was: --no-reset, then a 2nd commander callstr(firmware_bin),
]
result=subprocess.run(load_cmd, env=env)
# (no more 2nd `pyocd commander -c reset` step)
I'd expect this to drop the wedge incidence dramatically -- maybe entirely, maybe to "rare" depending on whether the reset itself also nudges the CDC. Worth testing.
If it still wedges after that, the architected answer is #595's lpc21isp path -- which sidesteps the composite HID entirely by going ISP-over-UART. (Currently lpc21isp isn't installed on this host, so I haven't been able to A/B that path empirically. The merged Rust LpcDeployer in fbuild#595 is the prerequisite.)
Acceptance criteria for closing this issue haven't shifted
The issue body's original requirement -- "deploy must always unwedge the shared VCOM" -- remains correct. The fix shape changes from "switch to SW reset" (already attempted, doesn't work) to one of:
A. Single-pyocd-call (cheapest; might resolve everything; test first)
Activity
zackees commentedon Jun 15, 2026
/clud-fix burn-down — skipped (downstream of #551)
Touched as part of the #586 meta sweep. This issue is strictly downstream of #551 (no LPC
Deployerexists yet, so there's nothing to attach the VCOM-unwedge logic to). Investigation report on #551 sketches the planned fix shape — including a dedicatedvcom_unwedge.rsmodule specifically for the acceptance criterion this issue tracks. Will re-attempt this one automatically once #551 lands the LPC deployer scaffold.Filed via Claude Code —
/clud-fixskill burn-down pass.feat(deploy/lpc): LpcDeployer Phase 1 — lpc21isp ISP-over-UART (closes …
zackees commentedon Jun 16, 2026
Confirmed wedge on 2026-06-15 with refined repro + likely actual trigger
Reproduced today running
bash autoresearch lpc845brk --pin-toggle-rx --upload-port COM10on Windows 10 against the LPC845-BRK. The wedge is real and consistent. Adding more diagnostic detail because the probable trigger is different from what this issue's original body assumed -- and that changes the fix shape.What FastLED's autoresearch actually does today
ci/autoresearch/phases.py:1684-1716invokes two separate pyocd subprocesses back-to-back:Each subprocess opens and closes the CMSIS-DAP HID interface independently. On the LPC845-BRK that interface is part of a composite USB device that also exposes the application VCOM CDC.
Observation today, after the merged work
I retested with the architected workarounds in place:
pyocd is using
--no-reseton the load +reset_type=sw(NVICSYSRESETREQ) on the separate commander -- not a hardware SRST, so the original "post-flash reset toggles the probe" hypothesis is ruled out for this exact code path.The CMSIS-DAP probe firmware on the LPC4322 / on-board debugger is not observably reset by
reset_type=sw(which is a target-side NVIC write, transparent to the probe).And yet the CDC VCOM still wedges into Windows error 31 every single time. Reproducibly. The follow-up sequence is:
pyocd load --no-reset-- opens HID, writes flash, closes HID. (Subprocess Esp32-s3 PSRAM use #1 exits.)pyocd commander -O reset_type=sw -c reset -c go -c quit-- opens HID again, sends NVIC reset to the target, closes HID. (Subprocess cdc on boot warning #2 exits.)The fact that this still happens with
--no-reset+reset_type=swmeans the wedge trigger is not the reset itself. It is something about the second HID open-close cycle on a composite device that confuses Windows' CDC driver.Refined root-cause hypothesis
The Windows usbccgp.sys (USB composite class generic parent driver) treats CMSIS-DAP HID + CDC as two function drivers under one device. When pyocd opens the HID, usbccgp serializes the HID interface. When pyocd closes it and then a different process re-opens it within a short window, usbccgp emits a function-level reset event on the device. That function-level reset doesn't affect the HID side (pyocd just re-handshakes) -- but the CDC sibling sees its endpoint cleared and the higher-level usbser.sys driver doesn't recover, going to error 31.
Two practical implications:
pyocd flash --reset(full unified command) orpyocd load -O reset_type=sw firmware.bin(single subprocess, default-on reset) keeps the HID open for the whole sequence.--no-reset+ separate commander pattern is the active trigger, not the reset semantic. This is whyreset_type=sw(which was added specifically for VCOM safety) doesn't save us -- it's not the reset that wedges the CDC, it's the inter-subprocess HID re-open.Proposed fix for the autoresearch path (one-line in
ci/autoresearch/phases.py)Collapse the two subprocesses into one:
I'd expect this to drop the wedge incidence dramatically -- maybe entirely, maybe to "rare" depending on whether the reset itself also nudges the CDC. Worth testing.
If it still wedges after that, the architected answer is #595's
lpc21isppath -- which sidesteps the composite HID entirely by going ISP-over-UART. (Currently lpc21isp isn't installed on this host, so I haven't been able to A/B that path empirically. The merged RustLpcDeployerin fbuild#595 is the prerequisite.)Acceptance criteria for closing this issue haven't shifted
The issue body's original requirement -- "deploy must always unwedge the shared VCOM" -- remains correct. The fix shape changes from "switch to SW reset" (already attempted, doesn't work) to one of:
lpc21ispISP-over-UART path (architected; requires the deployer wiring from feat(deploy/lpc): LpcDeployer Phase 1 — lpc21isp ISP-over-UART (closes #551, sidesteps #565) #595 and alpc21ispinstall)winusbIOCTL ordevconinvocation)I lean A first (try the unified
pyocd load -O reset_type=sw), B as the architected long-term answer, and C if neither A nor B holds 100% of the time.Cross-references from today's bench session
Happy to test the A fix locally and report back.
Filed via Claude Code on behalf of zachvorhies@protonmail.com.
ci(hooks): forbidden_commands.py — block pyocd/esptool/dfu-util/picot…
feat(deploy): resolve lpc21isp path via env / cache / tools / PATH (#921
feat(deploy): lpc21isp path resolver + baud/hex safety nets (#921, #927…
refactor(autoresearch): delegate all deployment to fbuild (removes py…